CABINET SPECIFICATION GUIDE

From a Suggested Size to an Approved Fixture.

Use these planning notes to review materials, holder fit and approval inputs. Suggested values remain subject to engineering, approved drawings and a representative sample.

01

Panel construction

15/18mm MDF or plywood are proposed starting points; 18mm is the initial main-body choice. Back panels 5–9mm and drawer bottoms 9–12mm require span and fixing checks. HPL worktops use an 18–25mm substrate. Specify finished thickness, edge sealing, material batch and finish sample.

02

Metal and decorative finishes

Initial steel frame candidates are 25 × 25 or 30 × 30mm tubes with 1.2–1.5mm walls. Aluminum frame sections begin around 25–40mm. Decorative stainless trim of 0.8–1.2mm is not a structural frame. Veneer around 0.3–0.6mm and exposed 1–2mm edge banding are starting choices, subject to supplier documentation.

03

Glazing and shelf support

An 8mm tempered top and 6mm side/door panels are planning candidates, not proof of structural adequacy. Larger spans may require divided supports and a different glass specification. Review edge treatment, holes, door hardware and support geometry. Acrylic/PMMA is not glass. UV protection must refer to an identified material and supporting report.

04

Lighting and electrical scope

Use the model-specific lighting proposal, with 4000K dimmable LEDs suggested for the standard sales counter. Confirm actual strip data, driver input/output, total power, dimmer compatibility, heat management and service access. Use the CRI target for component selection; destination-specific documents must match the supplied components.

05

Card and holder fitting

The supplied reference lists a 3 × 4in top loader as 76.2 × 101.6mm externally. Trial clear slots may begin at 80–85mm width and 110–120mm height, but fit the actual sleeve before machining. A 35pt label describes card cavity thickness, not the external thickness of the holder.

06

Graded cards and oversize formats

Measure the holder manufacturer, generation, card type, outer thickness and raised edges. A 90–100mm clear width and 145–160mm clear height are initial sample-grid suggestions only. They do not guarantee fit for every PSA, BGS or CGC holder. Oversize and landscape formats need their own layout.

07

Packs, boxes and capacity

Measure the complete outer retail package, including blister, wrap, hanging hole and protrusions. Confirm box weight, facings and shelf depth separately. Calculate display capacity using an actual merchandise arrangement; cabinet outer size alone cannot determine card capacity. Separate displayed cards from drawer inventory.

08

Hardware, stability and transport

Select lock/key arrangements, slide extension, hinges, feet or casters by configuration. Review loaded and unloaded stability, open drawers and wall anchoring. Packing requires separately measured package sizes, gross weights and numbered parts; do not use cabinet dimensions as packing dimensions.

09

Approval record and commercial fields

Record overall and clear dimensions, shelves, holder samples, materials, glass, hardware, lighting, load tests, assembly, accessories and drawing revision. MOQ, lead time and warranty remain order-specific. A proposed value should be labeled sample-verified only after the corresponding evidence is approved.

34 material and engineering parameters

Development parameters for drawing and sample review.

M01 / MDF

15/18mm; start with 18mm for main bodies. HPL, melamine or paint. Confirm density, sealed edges, finish brand and batch.

Confirm this parameter in the approved project specification.
M02 / Plywood

15/18mm starting options. HPL, veneer or paint. Confirm timber, plies, moisture condition, edge sealing and core quality.

Confirm this parameter in the approved project specification.
M03 / Particleboard

18mm starting option with melamine. Review fasteners, edge sealing and wear resistance; reinforce repeatedly assembled joints.

Confirm this parameter in the approved project specification.
M04 / Back / Drawer Bottom

Backs 5–9mm; drawer bottoms 9–12mm. Review span, load and fixings; thickness alone is not a load rating.

Confirm this parameter in the approved project specification.
M05 / HPL Countertop

18–25mm substrate; HPL thickness depends on brand. Confirm finished total thickness, texture, scratch requirement and color.

Confirm this parameter in the approved project specification.
M06 / Paint Finish

Primer and topcoat to the process sheet. Matte, semi-matte or gloss; confirm sample, sheen, color tolerance and full curing before packing.

Confirm this parameter in the approved project specification.
M07 / Wood Veneer

Approximately 0.3–0.6mm veneer as a starting option. Confirm species, grain direction, joints and approved sample.

Confirm this parameter in the approved project specification.
M08 / ABS / PVC Edge Banding

1–2mm exposed edge banding. Match panel color; specify glue line and rounded, burr-free merchandise-contact edges.

Confirm this parameter in the approved project specification.
M09 / Steel Frame

25 × 25 / 30 × 30mm tube with 1.2–1.5mm wall as initial options. Confirm grade, welding, supports and structural suitability.

Confirm this parameter in the approved project specification.
M10 / Aluminum Frame

Approximately 25–40mm frame sections. Match glazing channels, tracks and seals; confirm section drawing and connectors.

Confirm this parameter in the approved project specification.
M11 / Stainless Steel Trim

0.8–1.2mm decorative stainless sheet. Brushed, mirror or PVD options; decorative trim is not the load-bearing frame.

Confirm this parameter in the approved project specification.
M12 / Tempered Glass Top

8mm initial top; 8–10mm are candidates for larger spans. Confirm glazing drawing, support width, holes and edge work.

Confirm this parameter in the approved project specification.
M13 / Glass Sides / Doors

6mm initial sides/doors; 6–8mm candidates for large panels. Confirm door gaps, locks, holes and tracks.

Confirm this parameter in the approved project specification.
M14 / Glass Shelf

6–8mm initial shelves. Confirm clear span, support points and distributed-load testing before assigning a capacity.

Confirm this parameter in the approved project specification.
M15 / Low-Iron Glass

Match structural thickness. Low-iron glass improves visual clarity; it does not establish UV protection.

Confirm this parameter in the approved project specification.
M16 / Acrylic / PMMA

3–5mm initial card stands; cover thickness depends on panel size. Review polished edges, bonding, scratching and deflection.

Confirm this parameter in the approved project specification.
M17 / UV-Filtering Glazing

Specify glazing or film model separately. UV wavelength range, test method, report and service life require evidence; ordinary glass/PMMA is not assumed UV-filtering.

Confirm this parameter in the approved project specification.
M18 / Card Tray / Divider

3–5mm PMMA or lined panel trays. Use smooth edges and actual holder samples; confirm groove width/depth and handling clearance.

Confirm this parameter in the approved project specification.
M19 / Display Lining

Thin felt, microfiber or an approved inert pad. No bare-card contact or unsupported archival-grade claim; confirm dyes, odor and adhesive.

Confirm this parameter in the approved project specification.
M20 / Display Angle

15–30° from horizontal as an initial tray angle. Check reflections, obscured rear rows, row pitch and retaining-lip height.

Confirm this parameter in the approved project specification.
M21 / LED Color Temperature

4000K preferred; 3000/5000K options. Keep a consistent white light on card faces; colored light is for atmosphere. Confirm LED model/batch.

Confirm this parameter in the approved project specification.
M22 / Color Rendering Index

Lighting selection target: Ra ≥90. Check strip documentation and sample illumination.

Confirm this parameter in the approved project specification.
M23 / LED Strip Power

Approximately 4.8–9.6W/m initial strip options. Use aluminum heat dissipation and diffuser; calculate length, total load and temperature rise.

Confirm this parameter in the approved project specification.
M24 / LED Driver

DC24V is a candidate output; input follows destination. Confirm voltage, frequency, plug, dimming and manufacturer load headroom.

Confirm this parameter in the approved project specification.
M25 / Dimming / Timer

Switch with optional dimmer/timer. Confirm protocol, accessible controls and heat test; control brightness and exposure duration.

Confirm this parameter in the approved project specification.
M26 / Showcase Lock

Sliding/hinged showcase lock to door type. Optional keyed-alike or independent keys. A lock is not a certified burglary rating.

Confirm this parameter in the approved project specification.
M27 / Drawer Slides

350–550mm candidate slide lengths; optional full extension and soft-close. Confirm loaded drawer width, clearance and cycling test.

Confirm this parameter in the approved project specification.
M28 / Concealed Hinges

Approximately 95–110° candidate opening. Door thickness and weight determine quantity/model; confirm mounting and collisions.

Confirm this parameter in the approved project specification.
M29 / Plinth / Leveling Feet

80–120mm initial recessed plinth. Confirm total-height convention, leveling travel, floor and per-foot rated load.

Confirm this parameter in the approved project specification.
M30 / Lockable Casters

50–75mm candidate caster diameter with brakes. Select by total mass, floor and operation; review plate and rolling test.

Confirm this parameter in the approved project specification.
M31 / Anti-Tip / Wall Mounting

Steel brackets or connectors to a suitable substrate. Engineer attachment for tall, shallow-wall and multi-drawer units; test empty/loaded stability.

Confirm this parameter in the approved project specification.
M32 / Export Packaging

Corner guards, cushioning and carton/crate. Separate glass and secure shelves. Confirm numbered package dimensions and gross weights.

Confirm this parameter in the approved project specification.
M33 / Display Capacity

Use actual loaded count. Record holder model, rows, tiers and handling checks. Keep display capacity separate from drawer inventory.

Confirm this parameter in the approved project specification.
M34 / Material / Electrical Documents

Verify panel, glass and electrical documents separately for destination and scope. Component grades do not establish whole-cabinet certification.

Confirm this parameter in the approved project specification.

10 card and packaging fit checks

Fit the actual merchandise before machining slots or fixing shelf spacing. Record the tested holder or package size with the project drawings.

F01 / Bare card reference

63.5 × 88.9mm is the card size supported by the referenced Ultra PRO product, not a universal size for every TCG. Choose the protective sleeve before defining a display slot.

F02 / 3 × 4in top loader

The source gives an outer width and height of 76.2 × 101.6mm. Trial a clear width of 80–85mm and height of 110–120mm using the actual holder. Measure its outer thickness; 35pt describes card cavity thickness.

F03 / Small-format and double-sleeved cards

Measure the complete sleeve combination. Record the brand, model and single- or double-sleeve arrangement; fit the outermost sleeve.

F04 / Magnetic card holders

Specify the exact 35pt, 55pt, 100pt or other model. Measure the exterior and allow retrieval clearance. The point rating does not state the outer holder thickness.

F05 / Graded card holders

Measure the grading company, holder generation, card format, external thickness and raised edge. Initial trial cells may be 90–100mm wide and 145–160mm high; verify each actual holder.

F06 / Thick slabs and oversize cards

Use independently sized wide slots or compartments. Record the full outer envelope and finger clearance rather than assuming the standard slab grid will fit.

F07 / Landscape display

Lay out a separate landscape row using the rotated holder dimensions. Recalculate cards per row using its new displayed width.

F08 / Packs and blister packages

Measure the complete retail package. Record hanging-hole location, center of gravity and stocked row depth. Loose booster pack measurements do not describe blister packaging.

F09 / Sealed boxes and gift sets

Measure the shrink-wrapped exterior, box weight and planned boxes per shelf. Allow vertical and front retrieval space.

F10 / Binders and deck boxes

Measure closed exterior dimensions and opening movement. Upright storage may need retaining edges; flat storage needs retrieval room. Advertised card capacity is not the package size.

Quotation and approval fields

Complete these fields from the agreed drawings, component records and tests before production approval.

Model NumberRequired · To be confirmed
Product NameRequired · To be confirmed
ApplicationRequired · To be confirmed
Overall LengthRequired · To be confirmed
Overall DepthRequired · To be confirmed
Overall HeightRequired · To be confirmed
Dimensions in InchesOptional · To be confirmed
Clear Display DimensionsRequired · To be confirmed
Shelf DimensionsRequired · To be confirmed
Number of ShelvesRequired · To be confirmed
Shelf Adjustment PitchOptional · To be confirmed
Compatible Card HoldersRequired · To be confirmed
Clear Slot WidthRequired · To be confirmed
Clear Groove ThicknessRequired · To be confirmed
Clear Slot HeightRequired · To be confirmed
Tray AngleOptional · To be confirmed
Display CapacityRequired · To be confirmed
Cabinet MaterialRequired · To be confirmed
Frame MaterialRequired · To be confirmed
Surface FinishRequired · To be confirmed
Color / Finish CodeRequired · To be confirmed
Top GlassRequired · To be confirmed
Door / Side GlassRequired · To be confirmed
UV ProtectionOptional · To be confirmed
Door AccessRequired · To be confirmed
Locking SystemRequired · To be confirmed
Slides / HingesRequired when applicable · To be confirmed
Base / CastersRequired · To be confirmed
LightingRequired when applicable · To be confirmed
Color TemperatureRequired when applicable · To be confirmed
CRIRequired when applicable · To be confirmed
Rated PowerRequired when applicable · To be confirmed
Power Supply / PlugRequired when applicable · To be confirmed
Lighting ControlRequired when applicable · To be confirmed
Load Capacity per ShelfRequired · To be confirmed
InstallationRequired · To be confirmed
Net WeightRequired · To be confirmed
Package DimensionsRequired · To be confirmed
Gross WeightRequired · To be confirmed
AssemblyRequired · To be confirmed
Included AccessoriesRequired · To be confirmed
CustomizationRequired · To be confirmed
MOQRequired · To be confirmed
Lead TimeRequired · To be confirmed
WarrantyRequired · To be confirmed
Drawing RevisionInternal review · To be confirmed